What was found
INSPECTION TYPE:D, BULK CARGO COMPT STA 1920 TO 2040 RBL 53.45 FLOOR PANEL SUPPORT FOUND CORRODED. CORROSION R & R IAW SRM 51-10-02 & 51-20-01 REV 17, ORG 0.050" BLEND DEPTH 0.003", WIDTH 1" & LENGTH 1" WITHIN SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG, 101 LIMITATION, REV 17. EXCEPT STA 1942, RBL 53-45. THIS BLEND DEPTH 0.025"X 1" X 1". FINAL CUTOUT SIZE IS 2.5" X 0.75". FINAL REPAIR SIZE IS 5.75 IN LENGTH.