What was found
INSPECTION TYPE:D, M/DECK SCD DOOR SILL WEB CORRODED AT NR 9 LATCH FTG, STA 1900 WL 117. M/DECK SCD DOOR SILL WEB CORRODED AREA AT STA 1900, WL 117 REPAIRED IAW HX RS R-53-60-36979, REV A & EO B747-5320-42014-A. ORG. MATL IS 7075T6-.125", 0.085" THICKNESS REMAINED, BLEND OUT AREA IS 1.5"X1.5". THIS REPAIR IS CLASSIFIED AS A MINOR REPAIR.