What was found
INSPECTION TYPE:D, BULK CARGO COMPT STA 1920 TO 2160 CTR FLOOR PANEL SUPPORT SURFACE FOUND CORROSION. CORROSION REMOVED & REPROTECTED IAW SRM 51-10-02 & SRM 51-20-01. ORG: 0.050" BLENDED DEPTH: 0.004" WIDTH: 0.6" LENGTH" 2" WITHIN SRM 53-00-51 ALLOWABLE 1 FIG 101 LIMITS, REV 17.