What was found
INSPECTION TYPE:D, BULK CARGO COMPT STA 1920 TO 2040 LBL 45" FLOOR PANEL SUPPORT SURFACE FOUND CORRODED. CORROSION REMOVED & REPROTECTED IAW SRM 51-10-02 & SRM 51-20-01. ORG: 0.050" BLENDED DEPTH: 0.003" WIDTH: 1" LENGTH: 1" WITHIN SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG, 101 LIMITS, REV.17