What was found
INSPECTION TYPE:D, M/D STA 960 RT CREASE BEAM TO FRAME ATTACH ANGLE CRACKED AT STR 7R AREA. M/D STA 960, RT CREASE BEAM TO FRAME ATTACH ANGLE REPLACED & INSTALLED AT STR 7R AREA IAW HX RS R-53-20-37044, REV A & EO B747-5310-42616-A. THIS IS A CATEGORY A REPAIR & CLASSIFIED AS MINOR REPAIR REPETITIVE INSPECTIONS WILL BE ACCOMPLISHED IAW EO B747-5310-26850.