What was found
INSPECTION TYPE:4C, AFTER REMOVAL OF SPICE FITTING ON LONGERON 51L FOUND CORROSION STA 1129. R & R LONGERON AND SPLICE FITTING REF SRM 51-33-01 PG. 45, 30.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:4C, AFTER REMOVAL OF SPICE FITTING ON LONGERON 51L FOUND CORROSION STA 1129. R & R LONGERON AND SPLICE FITTING REF SRM 51-33-01 PG. 45, 30.