What was found
INSPECTION TYPE:C, FWD CARGO BILGE AREA AT BS 1019 LONGERON 51R, FOUND CORRODED. CORROSION EXCEED LIMITS IAW SRM 53-00-00 FIG 205. CORRODED AREA TRIMMED OFF & HFEC INSPECTION PERFORMED, NO CRACK EVIDENT. NEW LONGERON FABRICATED IAW DWG ADA8091, REV E & SPLICES FABRICATED IAW SRM 53-00 -05, FIG 201. LONGERON & SPLICES INSTALLED PER SRM 53-00-05 FIG 202 REPAIR 1 REV 47.