What was found
INSPECTION TYPE:C, LEFT MLG FLIPPER DOOR FWD EDGE, FOUND CRACKED. HFEC INSPECTION FOUND A CRACK APPROX .5 INCHES IN LENGTH. STOP DRILLED 0.25 DIA IAW SRM 52-82-01, FIG 202, REPAIR 1 VIEW A. HFEC INSPECTION CARRIED OUT, NO CRACK EVIDENT. REPAIR DOUBLER FABRICATED IAW SRM 52-82-01, FIG 202. REPAIR INSTALLED IAW SRM 52-82-01, FIG 202.