What was found
INSPECTION TYPE:4C, MAIN DECK CARGO, RT SIDE, FWD OF UPPER AUX TANK, CORROSION FOUND AT STRINGER 16, 27" INBD FROM LONGERON 27 RT AS MARKED. ACCOMPLISHED PERMANENT REPAIR IAW E0 MD11-5730-52276-A AND EA 011-5730 -01-A4928, REV I/R AT STR 15 AND 16 BETWEEN XCW81 TO XCW -118.