What was found
INSPECTION C8S4, CABIN FLOORBEAM CORRODED AND BARE METAL BS 879, LBL 2-21. BLENDED AREA IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS. PERFORMED HFEC ROTARY PROBE INSPECTION IAW NTM 51-00-16 PT6, NO CRACK INDICATIONS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.