What was found
DURING SG12 INSPECTION, AFT CARGO FLOOR SUPPORT BS 1290 DENTED. FOUND OUT OF LIMIT IAW SRM 53-00-53-1A-1. CUTOUT DAMAGED SECTION OF FLOOR SUPPORT FROM BS 1288-1291 IAW SRM 53-00-53-2R-1 DETAIL IV. HFEC INSPECTED CUTOUT IAW NDTM PT6 51-00-19, NO CRACK INDICATIONS NOTED. FABRICATED PART 4 FILLER IAW SRM 53-00.