INSPECTION 10S2, CORROSION FOUND ON FLOOR SUPPORT BS 1040 - 1080, RBL 48. FABRICATED NEW FLOOR SUPPORT IAW DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION 10S2, CORROSION FOUND ON FLOOR SUPPORT BS 1040 - 1080, RBL 48. FABRICATED NEW FLOOR SUPPORT IAW DWG.