What was found
AT 500 AGL A LEVEL 3 ENGINE FIRE ALERT. EMERGENCY DECLARED, LANDED AND SHUTDOWN NR 3 ENGINE. REPLACED NR 3 ENG FDCU IAW MM 26-11-02. REPLACED FIRE DETECTOR DH4-DH7 IAW MM 26-11-03. R & R TERMINAL BLOCK TB3 IAW MM 71-50-04-000-808 AND 71-50-04-400-808. REPLACED NR 3 ENG FIRE DETECTOR HARNESS ALOP H4 TO H23 IAW MM 71-50-04 & 71-50-20-01-32. REPLACED NR 3 ENG A LOOP HARNESS. BITE CHECK OK. RAN ENGINES. ACFT OK FOR SERVICE.