What was found
INSPECTION TYPE:C, LT INBD ELEVATOR UPPER SURFACE DELAMINATED FIBERGLASS PREPREG LAY UP, REPAIR PERFORMED IAW SRM 51-70-07, PAR 5A, 1, FIG 5, REV 71.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, LT INBD ELEVATOR UPPER SURFACE DELAMINATED FIBERGLASS PREPREG LAY UP, REPAIR PERFORMED IAW SRM 51-70-07, PAR 5A, 1, FIG 5, REV 71.