What was found
INSPECTION TYPE:C, CABIN CENTER RT FLOOR SUPPORT HAS CORROSION STA 1010, RBL 32. DOT 35102, REWORKED DAMAGED AREA IAW 51-10-02-0G FOUND TO BE LIMITS IAW SRM 53-00-51-1A-1 DETAIL II, ORIGINAL .053 AFTER REWORK MATERIAL LOSS .006. REMOVED FLOOR SUPPORT AT STA 1010 RBL IAW SRM 51-40-02-0G. FABRICATED FLOOR SUPPORT ON MAE TRAVELER T15/1128430 & LOCATED AND DRILLED IAW SRM 51-40-05.