As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C, MAIN DECK FLOORBOARD 231XJF HAS DELAMINATION AND EDGE DAMAGE. 122-0181. FABBED NEW PANEL 231XJF PN 143N5457-95 FROM A402H-48X144 BAT 2664589 IAW SREO 5320-9692, APPENDIX B 1-2. 2. RESTORE LOWER SURFACE IN STEP OUT AREA IAW SREO 5320-9692. SCUFF SANDED AND PREP IT THE BONDING AREA IAW EO 5320-9692-H AND SRM 53-00-50-2R-1.04. FABRICATE 3 EA PLIES BATCH NR 2753728 IAW 5320-9692-H AND SRM 53-00.