What was found
INSPECTION TYPE: C, MAIN CARGO DECK FLOOR SHEAR WEB AT RBL 35 BETWEEN STA 345 AND STA 365 HAS CORROSION, DOT 82-0351, REMOVED FASTENERS ,07 EA, FOR ACCESS IAW SRM 51-40-02-06. REMOVED CORROSION AREA IAW SRM 51-10-02-06 ORIGNAL MATERIAL .100, MATERIAL .2055, 0.12 REMAINING MATERIAL .088 FOUND TO BE WITHIN LIMITS IAW SRM 53-10-51-1A-2 USED ULTRASONIC OK TO TREAT AND PRIME AREA 4. TREATED AND PRIMED AREA IAW SRM 51-20-01-06. 5. OK TO INSTALL FASTENERS.