What was found
INSPECTION TYPE:C, MAIN CARGO DECK FLOOR SHEAR WEB AT RBL 35 BET STA 345 AND 365 HAS CORROSION. REMOVED FASTENERS 07 EA FOR ACCESS IAW SRM 51-40-02-0G. REMOVED CORROSION AREA IAW SRM 51-10-02-06, ORIGINAL MATERIAL .100 MAT LOSS .012 REMAINING MATERIAL .088 FOUND TO BE WITHIN LIMITS IAW SRM 53-10-51-1A-2 USED ULTRA SONIC ID T14217, DUE 3. OK TO TREAT AND PRIME AREA. TREATED AND PRIMED AREA IAW SRM 51-20-01-06. 5. OK TO INSTALL FASTENERS 07 EA.