What was found
FLAME OUT LEVEL NR 2 LAT FUEL UNBALANCE CHECK LIST ACCOMPLISH 1 FILL VALVE STUCK OPEN MULTIPLE ATTEMPTS TO CLOSE NR 1 FILL VALVE CYCLED BACK TO AUTO AFTER MANUALLY BALANCING FUEL INADVERTANT ENGINE NR 2 SHUTDOWN DUE TO F/O TURNED OFF NR 2 TRANSFEED PRIOR TO TURNING TANK NR 2 PUMPS ON PERFORMED RTS ON FSC IAW AMM 28-08-01-741-801. ALL TESTS PASS. ACFT OK TO CONTINUE. THIS REPLACES SDR IPXA2015151389060 DUE TO INCORRECT DATE.