What was found
INSPECTION TYPE:C, NUMEROUS AREAS OF CORROSION ON AFT PIT RT TRANSITION PANEL UPPER SURFACE AT THE DOWN FITTINGS AND INBD NUTPLATE ROWS BS 1530-1640. 53-141. REMOVED SURFACE CORROSION ON AFT PIT RH TRANSITION PANEL FROM STA 1530-1640 IAW SRM 51-10-02-0G. CHECK LIMITS ORIGINAL MATERIAL .063 , MATERIAL LOSS .025 REMAINING MATERIAL .038 FOUND TO BE OUT OF LIMITS FS 1540 IAW SRM 53-00-53-1A-1, FIG 101, DETAIL V, TR4 T17809. REMOVED DAMAGE SECTION OF TRANSITION PANEL FROM FS 1530-1565 IAW SRM 51-40-02-0G, RECEIVED.