What was found
INSPECTION TYPE:3C, SHEAR TIE CRACKED IN 311 COMPARTMENT CEILING BS 2047. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT SHEAR TIE IAW DWG AJC7021 AND SRM 51-33-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:3C, SHEAR TIE CRACKED IN 311 COMPARTMENT CEILING BS 2047. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT SHEAR TIE IAW DWG AJC7021 AND SRM 51-33-01.