What was found
INSPECTION TYPE:C, CABIN FLOOR WEB BS140 AT LT MOST OTBD CORNER CRACKED. M/D BS140-160 LT OTBD MOST FWD CORNER FLOOR WEB IS REPAIRED IAW SRM 53-10-51-2R-7, FIG 201, REV 33. THIS IS CAT B REPAIR, SUPPLIMENT INSPECTIONS ARE REQIRED IAW SRM 53-10-51-2R-7, TABLE 202, REV 33. INSP THRESHOLD IS 15,000 FLT CYC AFTER REPAIR INSTALLATION REPEAT INSP INTERVAL IS 3,000 FLT CYC.