What was found
INSPECTION TYPE:C, FUSELAGE SKIN, BS207 BETWEEN S-14R AND S-15R LIGHTNING STRIKE. REPAIRED LIGHTNING STRIKE AT FUSELAGE SKIN BS207 BETWEEN S-14R AND S-15R IAW SRM 53-00-01-2R-6 SECTION I, PARAGRAPHS 1, 2, AND 3 INSTALLED REPAIR FASTENER.