What was found
INSPECTION TYPE: C, MAIN DECK BS 2231 FRAME, STR 16L WAS FOUND WITH ONE FASTENER HOLE CRACKED AT THE FORWARD INNER CHORD RUNNING AT 5 O/C POSITION APPROXIMATELY 0.020". FRAME OVERSIZED IAW EO NT B747-5310-27767-F, FIG 4 CIRCLE NOTE 3, PG C13, ITEM 26 AND HX RI NO RI-53-60-10991, REV A.