As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
"C HYD SYS PRESSURE" ALERT AND ASSOCIATED"SYS PRESSURE" LIGHT ILLUMUNATED ON CLIMBOUT AFTER SELECTING ADP PUMP OFF IAW MEL TURNED ADP BACK TO "ON" POSITION IAW QRH PROCEDURE. EICAS MSG AND PRESSURE LIGHT REMAINED. R & R CENTER SYSTEM PRESSURE TRANSMITTER IAW MM REF 29.31.01.004.014 AS PRECAUTIONARY. OPS & LEAK CHECKS NORMAL. R & R CENTER SYSTEM PRESSURE SWITCH IAW MM 29.11.09.024.001. OPS & LEAK CHECKS NORMAL SYSTEM NOW OPERATES NORMAL.