What was found
INSPECTION TYPE:SV, DENT BEHIND RADOME ON FWD BULKHEAD AT APPROX 3:30 POS DENT .275 5.2" X 4.3. REQUIRE HI FREQUENCY HFEC AREA, NO CRACKS NOTED IAW REF NDTM PART 6-51-00-19. C/W EO B757-5310-58824A. DEFERRED DAMAGE TO FWD PRESS BULKHEAD. MUST FLY. INSTALLED PERM REPAIR IAW REF G19217, REV B. DEFERRAL CLOSED.