What was found
INSPECTION TYPE:ETOP, AIR TURNBACK DUE TO RT FMC FAIL, EICAS CANT DNL EICAS DISPLAY, RT IRS ON DC F/O RMI FAIL, LOWER EICAS BLANK F/O FLT DIR, MAP AND VTR, VOR/ DME FOUND C/B C307, 115VAC BUS RT SECT 2 IN P6 PANEL POP. RAN BOTH ENGINES AND BITE CK BPCU NO FAULTS FOUND. PARTS ON ORDER REF REQ E146509 FC, 1071953. C/W ITEM T169552, 5OOV & 1KV MEG OHMED HARNESS TO GROUND AND TO EACH OTHER AT A2-B2-C2, ALL SHOW 999M OHMS. R & R C/B C307 OPS. GOOD AT THIS TIME.