What was found
INSPECTION TYPE:3C, LONGERON 19R CORRODED UNDER FLANGE BS 1140. REMOVED CORROSION ON LONGERON 19R AT BS 1140, REF SRM 53-00-00. MATERIAL REMOVED IS .008, REMAINING IS .092 AND WITHIN LIMITS OF SRM 53-00-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:3C, LONGERON 19R CORRODED UNDER FLANGE BS 1140. REMOVED CORROSION ON LONGERON 19R AT BS 1140, REF SRM 53-00-00. MATERIAL REMOVED IS .008, REMAINING IS .092 AND WITHIN LIMITS OF SRM 53-00-00.