What was found
INSPECTION TYPE: 3C, RT WING INBD FLAP VANE HAS 2 EA AREAS OF DELAMINATION ON LOWER OTBD SURFACE ACCOMPLISHED PERMANENT REPAIR ON RT WING INBD FLAP VANE OTBD LOWER SURFACE, 40" TO 46" FROM OTBD EDGE, 13.5" TO 4.5" FROM T/E, 5.5" TO 8" WIDE IAW SRM 57-50-80, REPAIR 2.