What was found
INSPECTION TYPE:3C, AREA OF LIGHT SURFACE CORROSION ON FLOOR PANEL SUPPORT IN MAIN CARGO AT BS 1361, RBL 114. ACCOMPLISHED BLEND REPAIR ON FLOOR PANEL SUPPORT IN MAIN CARGO BS 1361, RBL 114 IAW SRM 51-21-01 AND SRM 53-00-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:3C, AREA OF LIGHT SURFACE CORROSION ON FLOOR PANEL SUPPORT IN MAIN CARGO AT BS 1361, RBL 114. ACCOMPLISHED BLEND REPAIR ON FLOOR PANEL SUPPORT IN MAIN CARGO BS 1361, RBL 114 IAW SRM 51-21-01 AND SRM 53-00-00.