What was found
INSPECTION TYPE: 3C, WHILE INSPECTING CORROSION REMOVAL, FOUND VERTICAL STIFFENER BEAM WITH HEAVY CORROSION AT BS 6-70, ABOVE L43L. INSTALLED PERMANENT REPAIR BY REPLACEMENT OF STANCHION BS 6-70 X=57.00 IAW EA 011-5310-01-A6128, REV I/R AND EO MD11-5320-60055-A.