What was found
INSPECTION TYPE:2C, RIGID CARGO BARRIER WALL HAS A CRACK AT NR 10 FITTING INNNER LOWER CLOSE OUT AREA BS 488 X=72.5 ACCOMPLISHED CRACK REPAIR ON RCB INNER LOWER CLOSEOUT AREA BS 488 X=-72.5 IAW EA 011-5310-01-A6188, REV I/R AND EO MD11-5310-60517-A.