What was found
HYDRAULIC PRESSURE SYS NR 1 DURING CRUISE. SYNOPTICS SHOWED ALL PUMPS INOPERATIVE. EMERGENCY DECLARED. R & R ADP TURBINE DRIVE IAW AMM 29-11-08-401. R & R ADP ASSY IAW AMM 29-11-17-401. LEAK AND OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HYDRAULIC PRESSURE SYS NR 1 DURING CRUISE. SYNOPTICS SHOWED ALL PUMPS INOPERATIVE. EMERGENCY DECLARED. R & R ADP TURBINE DRIVE IAW AMM 29-11-08-401. R & R ADP ASSY IAW AMM 29-11-17-401. LEAK AND OPS CHECK GOOD.