INSPECTION TYPE: C, DURING MAJOR MAINTENANCE VISIT 6995 FOUND DENT AT BULK CARGO DOOR FWD LOWER CORNER WITHIN ALLOWABLE DAMAGE, REF EGAT NRC FFU05019 EVALUATED DAMAGE IAW SRM 52-30-01-1A-1, DETAIL VI REV 65.00 INFORMATION SUBMITTED FOR ADM DENT WITHIN ALLOWABLE DAMAGE LIMIT.