What was found
INSPECTION TYPE: 1C5Y, TRAPPED WATER INDICATIONS FOUND, LT ELEVATOR UPPER SURFACE INSPECTION AREA NR 1, MARKED NR 1, 2.5" X 3"X 23.5" OTBD OF ER2, FWD OF THE T/E FASTENER. REMOVED DAMAGED SKIN & CURE, REPLACED CORE & CURED, REPLACED DAMAGED SKIN & CURED, APPLIED SURFACED RESTORATION IAW EO A300-2030-49908-A.