What was found
INSPECTION TYPE:1C5Y, TRAPPED WATER INDICATION, FOUND LT ELEVATOR UPPER SURFACE. INSPECTION AREA NR 1, MARKED NR 3, 2.5" X 2" X 8.5" OTBD OF ER 2, FWD OF THE T/E FASTENER. REMOVED DAMAGED SKIN AND CURE, REPLACED CORE & CURED. REPLACED DAMAGED SKIN & CURED, APPLIED SURFACED RESTORATION IAW EO A300-2030-49908-A.