What was found
CORNER FLAP SYS 1, FLAP SYS 2, FAULT. FLAPS STUCK, 15/15. PERFORMED BITE ON SFCC 1 AND 2 AND GOT A KRUGER RT EXTEND SW MESSAGE. TROUBLESHOT IAW TSM 27-80-12,102. OPS CHECKED NORMAL. COULDN’T FIND ANY WIRING PROBLEMS AND COULD NOT DUPLICATE ORIGINAL WRITE UP ON THE GROUND. NO CURRENT HISTORY. SYS OK FOR SERVICE.