Service difficulty report · Clamp · Doug MD11F

Difficulty date
October 2, 2016
Submitted
October 3, 2016
Operation
Air carrier
Aircraft
N274UP
Make and model
Doug MD11F
Aircraft serial
48575
Aircraft time
65,008 hours, 11,946 cycles
Engine
Pwa PW4460
Part
Clamp
Condition
Leaking
Location
Nr 2 Manifold
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
J, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MANIFOLD 2 FAILED WARNING RECEIVED IN FLIGHT. FOLLOWED AOM CHECKLIST, THE NR 2 ENGINE THRUST REDUCED TO EXTINGUISH WARNING. NOTE - THE NR 2 BLEED VALVE INDICATED OPEN THE ENTIRE TIME. EMERGENCY DECLARED. PERFORMED FIM 36-23-03, FOUND SEVERAL CLAMPS ON THE NR 2 PNEUMATIC MANIFOLD. TIGHTENED THE CLAMPS IAW MM 36-14-02. PERFORMED LEAK CHECK IAW MM 36-14-03. ALL SATIS NO FURTHER AIR LEAKS NOTED.

More about the Doug MD-11F