What was found
INSPECTION TYPE: 3C, RT INBD FLAP HINGE FAIRING OB SIDE PANEL LANDING CORRODED BEYOND ALLOWABLE LIMTS. REMOVED, FABRICATED AND INSTALLED REPLACEMENT PANEL LANDING IAW DWG ARC2540 AND SRM 51-35-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: 3C, RT INBD FLAP HINGE FAIRING OB SIDE PANEL LANDING CORRODED BEYOND ALLOWABLE LIMTS. REMOVED, FABRICATED AND INSTALLED REPLACEMENT PANEL LANDING IAW DWG ARC2540 AND SRM 51-35-02.