What was found
INSPECTION TYPE: 1C, FRAME 40 MIDDLE FASTENER HOLE NR 2 HAS A CRACK INDICATION AT THE 6 O'CLOCK POSITION. REAMED THE FRAME AND INSTALLED A SECOND OVERSIZE FASTENER WITH WASHERS AND NUT IAW EO A300-5710-62125-B AND REO G20300, REV "D".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: 1C, FRAME 40 MIDDLE FASTENER HOLE NR 2 HAS A CRACK INDICATION AT THE 6 O'CLOCK POSITION. REAMED THE FRAME AND INSTALLED A SECOND OVERSIZE FASTENER WITH WASHERS AND NUT IAW EO A300-5710-62125-B AND REO G20300, REV "D".