What was found
INSPECTION TYPE: 2C, FLOOR SUPPORT CORRODED BS 424 - 453, RBL 65. REMOVED, FABRICATED, AND INSTALLED A REPLACEMENT FLOOR SUPPORT BETWEEN BS 380 - 450 IAW DWG ABA7341, AND SRM 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: 2C, FLOOR SUPPORT CORRODED BS 424 - 453, RBL 65. REMOVED, FABRICATED, AND INSTALLED A REPLACEMENT FLOOR SUPPORT BETWEEN BS 380 - 450 IAW DWG ABA7341, AND SRM 51-31-01.