What was found
INSPECTION TYPE: 3C, RT WING TANK UPPER ACCESS PANEL 634BT, AT XORS 506, RIB STIFFNER IS CRACKED. REMOVED, FABRICATED AND REPLACED THE RIB STIFFNER IAW DWG ARB0358, AND SRM 51-33-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: 3C, RT WING TANK UPPER ACCESS PANEL 634BT, AT XORS 506, RIB STIFFNER IS CRACKED. REMOVED, FABRICATED AND REPLACED THE RIB STIFFNER IAW DWG ARB0358, AND SRM 51-33-01.