What was found
DURING CLIMB, THE RT ENGINE HPSOV CAUTION MESSAGE ILLUMINATED, RAN THE CHECK LIST AND COULD NOT GET BLEED LIGHT TO GO OUT. TROUBLESHOT IAW FIM 36-10-00. FOUND THE HPSOV LOOSE AT VALVE STEM AND LEAKING THRU STEM. R & R AREA AT BOTTOM OF VALVE. R&R'D HPSOV ON RT ENGINE IAW AMM 36-11-07. OPS CHECKED NORMAL.