As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ATB - CLIMBING THROUGH FL 240 GOT LEVEL 1 HYD ALERT FOLLOWED QUICKLY BY LEVEL 2 HYD 3 FAIL, ALL FLUID NEARLY GONE. REMOVED STAB TRIM RT MOTOR IAW AMM 27-43-30-400-801. INSTALLED RT STAB TRIM HYD MOTOR IAW AMM 27-43-30-400-801 EFF SOURCE REF 27-43-20-01.