What was found
CREW ENTRY DOOR LEAKS ALONG FLOOR, BEGAN AT FL150 & CONTINUED ENROUTE. T/S PERF ACC FIM 52-12-04-00 REV 120.02. FOUND DOOR SEAL 4" OUT OF ITS RAIL. RESEATED DOOR SEAL ACC AMM 52-09-01 REV 120.03. VISUAL CHK OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CREW ENTRY DOOR LEAKS ALONG FLOOR, BEGAN AT FL150 & CONTINUED ENROUTE. T/S PERF ACC FIM 52-12-04-00 REV 120.02. FOUND DOOR SEAL 4" OUT OF ITS RAIL. RESEATED DOOR SEAL ACC AMM 52-09-01 REV 120.03. VISUAL CHK OK.