What was found
INSPECTION TYPE: 3C, FWD CARGO BAY FLOORBEAM CRACKED ABOVE LONGERON 43L AT BS 6-70. REMOVED, FABRICATED, AND INSTALLED A REPLACEMENT FLOORBEAM IAW DWG ADA7667, AND SRM 51-33-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: 3C, FWD CARGO BAY FLOORBEAM CRACKED ABOVE LONGERON 43L AT BS 6-70. REMOVED, FABRICATED, AND INSTALLED A REPLACEMENT FLOORBEAM IAW DWG ADA7667, AND SRM 51-33-01.