What was found
DURING DEPARTURE, THE LEADING EDGE ASSYMETRY DISPLAYED. RAN QRH PROCEDURE AND UNABLE TO DEPLOY FLAPS HYDRAULICALLY. SET FLAPS WITH ATERNATE METHOD IAW QRH PROCEDURE. TROUBLESHOT IAW FIM 32-09-00-990-803, FOUND DEBRIS AND GREESE ON SENSOR AND STOP AT 276. CLEANED, PERFORMED SYSTEM TEST IAW BLOCK 7, NO FAULTS SHOWN. ALSO RAN FLAPS AND SLATS SEVERAL TIMES, NO PROBLEMS. ACFT OK FOR SERVICE.