What was found
APU GEN OFF LIGHT, NO RESET INFIGHT TURNBACK, ONE ELECT POWER SOURCE. AHM SHOWS AT 370' APU COULDN'T MAINTAIN 95%. R & R THE APU FUEL CONTROL IAW MM 49-31-01, OPS AND LEAK CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU GEN OFF LIGHT, NO RESET INFIGHT TURNBACK, ONE ELECT POWER SOURCE. AHM SHOWS AT 370' APU COULDN'T MAINTAIN 95%. R & R THE APU FUEL CONTROL IAW MM 49-31-01, OPS AND LEAK CHECKED GOOD.