As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:N/AREF DEFERRAL M 622633 L1 DOOR -- PASS DOOR ELECTRIC ACTUATORS- CGO CONFIG- L1 & R1 ONLY PERM REPAIR. BEARING BUSHING SEIZED ON INPUT SHAFT TO UPPER LIMIT SWITCH. INSTALLED L1 AND R1 DOOR OPEN LIMIT SWITCH ADJUSTMENT. OPS CK GOOD. REF AMM 52-11-02-830-805. DMP REVERSED. PLACARD REMOVED. CLEARED DMI LOG. THIS CLEARS DEF M622633. EFF SOURCE REF MM 52-11-20.