As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:N/AWHEN EMERGENCY LIGHTS SWITCH PLACED IN DISARM,EMERGENCY LIGHT S ALL ILLUMINATE AND NO DISARM LIGHT IN LIGHT ASSY.TRIED NEW POWER SUPPLY UNIT,NO HELP.INSTALLED AND REMAVED AND INSTALLED ORIGINAL PART PER A300 MM CHPT 33-51-14-0401REPLACED VU436 PANEL PER CHPT 20 STANDARD PRACTICES AND PERFORMED ALL REQUIRED OPS CKS SUCCESSFULLY FOR VU436 PANEL CHANGE PER A300 MM CHPT 31-10-00-0201